A.R.MacLeod, H.S.Gill University of Bath, 2016 ** The condition for use of these models is that the following publication is cited: ** A.R.MacLeod, H.Rose, H.S.Gill, A Validated Open-Source Multi-Solver Fourth Generation Composite Femur Model, Journal of Biomechanical Engineering, 2016 The files contained in this directory are for the composite femur model F10 discussed in the publication. All models are for the converged 0.75mm mesh size detailed in the publication. The ABAQUS input file: F10_ABAQUS.inp The ANSYS input file: F10_ANSYS.ans The FEBIO geometry and main input files: F10_FEBIO_GEOM.feb F10_FEBIO_MAIN.feb The predicted equivalent strains for each of the models is given is the 'Results' files: Results_F10_Abaqus.txt Results_F10_Ansys.txt Results_F10_FEBio.txt In these files, rows 1-4 represent strain gauge locations 1-4. There are 11 load increments for each location: 0 to 500 N in 50 N increments. The experimental results are also provided in an identical format: Results_F10_EXPERIMENTAL_STRAINS.txt