<?xml version='1.0' encoding='utf-8'?>
<eprints xmlns='http://eprints.org/ep2/data/2.0'>
  <eprint id='https://researchdata.bath.ac.uk/id/eprint/1275'>
    <eprintid>1275</eprintid>
    <rev_number>26</rev_number>
    <documents>
      <document id='https://researchdata.bath.ac.uk/id/document/17131'>
        <docid>17131</docid>
        <rev_number>3</rev_number>
        <files>
          <file id='https://researchdata.bath.ac.uk/id/file/60666'>
            <fileid>60666</fileid>
            <datasetid>document</datasetid>
            <objectid>17131</objectid>
            <filename>Comparison.xlsx</filename>
            <mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type>
            <hash>2b7972dd3f8e007262215e05b4d40c1c</hash>
            <hash_type>MD5</hash_type>
            <filesize>239326</filesize>
            <mtime>2023-05-11 09:25:28</mtime>
            <url>https://researchdata.bath.ac.uk/1275/1/Comparison.xlsx</url>
          </file>
        </files>
        <eprintid>1275</eprintid>
        <pos>1</pos>
        <placement>1</placement>
        <mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type>
        <format>other</format>
        <formatdesc>excel spreadsheet containing the master data files and graphs of the fibrous plaster &apos;pull-off&apos; adhesion tests.</formatdesc>
        <language>en</language>
        <security>public</security>
        <license>cc_by</license>
        <main>Comparison.xlsx</main>
        <content>data</content>
      </document>
      <document id='https://researchdata.bath.ac.uk/id/document/17132'>
        <docid>17132</docid>
        <rev_number>3</rev_number>
        <files>
          <file id='https://researchdata.bath.ac.uk/id/file/60668'>
            <fileid>60668</fileid>
            <datasetid>document</datasetid>
            <objectid>17132</objectid>
            <filename>Origin data analysis of sample groups.zip</filename>
            <mime_type>application/zip</mime_type>
            <hash>b6004faf7b8758e860fb950cbd5e1cd9</hash>
            <hash_type>MD5</hash_type>
            <filesize>199351559</filesize>
            <mtime>2023-05-11 09:30:02</mtime>
            <url>https://researchdata.bath.ac.uk/1275/2/Origin%20data%20analysis%20of%20sample%20groups.zip</url>
          </file>
        </files>
        <eprintid>1275</eprintid>
        <pos>2</pos>
        <placement>2</placement>
        <mime_type>application/zip</mime_type>
        <format>other</format>
        <formatdesc>Detailed individual graphs of every test specimen in very sample group, with analysis of data performed concerning maximum load, strength and energy (work done, area under the grapoh curve) performed in Origin software.</formatdesc>
        <language>en</language>
        <security>public</security>
        <license>cc_by</license>
        <main>Origin data analysis of sample groups.zip</main>
        <content>data</content>
      </document>
    </documents>
    <eprint_status>archive</eprint_status>
    <userid>7650</userid>
    <dir>disk0/00/00/12/75</dir>
    <datestamp>2023-12-21 16:43:11</datestamp>
    <lastmod>2024-07-10 13:21:54</lastmod>
    <status_changed>2023-12-21 16:43:11</status_changed>
    <type>data_collection</type>
    <metadata_visibility>show</metadata_visibility>
    <creators>
      <item>
        <name>
          <family>Dams</family>
          <given>Barrie</given>
        </name>
        <id>B.Dams@bath.ac.uk</id>
        <orcid>0000-0001-7081-5457</orcid>
        <affiliation>University of Bath</affiliation>
        <contact>TRUE</contact>
      </item>
    </creators>
    <contributors>
      <item>
        <type>DataCollector</type>
        <name>
          <family>Dams</family>
          <given>Barrie</given>
        </name>
        <id>B.Dams@bath.ac.uk</id>
        <orcid>0000-0001-7081-5457</orcid>
        <affiliation>University of Bath</affiliation>
      </item>
    </contributors>
    <title>Dataset for the results of fibrous plaster tests: Pull-off samples tensile tests.</title>
    <subjects>
      <item>CP0020</item>
      <item>CP0070</item>
      <item>GE0030</item>
    </subjects>
    <divisions>
      <item>dept_civ_eng</item>
    </divisions>
    <keywords>Fibrous plaster, hessian fibres, Pull-off tests, jesmonite, fibreglass mat, quadaxial fibres, aramid gel, tensile tests</keywords>
    <note>Data is available in Microsoft Excel spread sheets and Origin software output.</note>
    <abstract>The data concerns the tests conducted to date concerning fibrous plaster pull-off test samples. Samples were made and tested in the laboratories of the University of Bath. Tensile tests were performed on &apos;pull-off&apos; samples where an attached cylinder was pulled from a base plate to test the adhesion of the cylinder material to the base plate material.</abstract>
    <date>2023-09-13</date>
    <publisher>University of Bath</publisher>
    <full_text_status>public</full_text_status>
    <lay_summary>Fibrous plaster tests have been conducted - fibrous plaster consists of gypsum plaster, hessian fibres and often a steel wire. It has been used for ceilings and as decorative features in theatres, civic buildings and private residences.</lay_summary>
    <corp_contributors>
      <item>
        <type>RightsHolder</type>
        <corpname>University of Bath</corpname>
      </item>
    </corp_contributors>
    <funding>
      <item>
        <funder_name>Leverhulme Trust</funder_name>
        <funder_id>https://doi.org/10.13039/501100000275</funder_id>
        <grant_id>RPG-2021-147</grant_id>
        <project_name>An overlooked heritage – Revealing the fibrous plaster ceilings of the UK</project_name>
      </item>
      <item>
        <funder_name>Historic England</funder_name>
        <funder_id>https://doi.org/10.13039/501100023881</funder_id>
        <project_name>Fibrous Plaster - Phase 2</project_name>
      </item>
    </funding>
    <research_centres>
      <item>cent_innov</item>
    </research_centres>
    <collection_method>Pull-Off: Twelve specimens each from multiple sample groups which consisted of a new cylinder element attached to a base plate, and the cylinder pulled off the base plate using tensile loading on a bespoke test rig. Sample groups included both hessian and quadaxial glass fibres, gypsum plaster, jesmonite and aramid gel. Bases were both clean and &apos;dirty&apos; - with historic mould applied.</collection_method>
    <techinfo>Pull-off: 100 kN capacity test rig Dartec Universal Testing Machine, displacement controlled tensile loading at 0.2 mm/min.</techinfo>
    <collection_date>
      <date_from>2020-10-01</date_from>
      <date_to>2022-09-30</date_to>
    </collection_date>
    <language>en</language>
    <version>1</version>
    <doi>10.15125/BATH-01275</doi>
    <related_resources>
      <item>
        <link>https://doi.org/10.1617/s11527-023-02239-0</link>
        <type>pub</type>
      </item>
    </related_resources>
    <access_types>
      <item>open</item>
    </access_types>
    <resourcetype>
      <general>Dataset</general>
    </resourcetype>
  </eprint>
</eprints>
