Six cob cylinders were manufactured at the facilities of the Department of Civil, Structural and Environmental Engineering, Trinity College Dublin. Three cylinders were tested in compression under force control at a rate of 100 N/s and the other three under displacement control at a rate of 15 mm/min during 3 min. The raw data file contains all the data points collected for load (N), test time (s) and displacement (mm) for each cylinder.