<?xml version="1.0" encoding="UTF-8" ?>
<documents xmlns="http://eprints.org/ep2/data/2.0"><document id="https://researchdata.bath.ac.uk/id/document/19707"><docid>19707</docid><rev_number>10</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/80543"><fileid>80543</fileid><datasetid>document</datasetid><objectid>19707</objectid><filename>SEM_Wall_thickness_results.xlsx</filename><mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type><hash>0bf4f0cb4ac4fc9c7261bce0983faf0d</hash><hash_type>MD5</hash_type><filesize>9371741</filesize><mtime>2025-12-17 14:03:22</mtime><url>https://researchdata.bath.ac.uk/1625/3/SEM_Wall_thickness_results.xlsx</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>3</pos><placement>3</placement><mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type><format>other</format><formatdesc>Measurements of the freeze-cast PZT NCE51 ceramic wall thickness fabricated at cooling rates ranging from 1 to 4 °C/min.</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>SEM_Wall_thickness_results.xlsx</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19708"><docid>19708</docid><rev_number>10</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/80546"><fileid>80546</fileid><datasetid>document</datasetid><objectid>19708</objectid><filename>Impedance data.zip</filename><mime_type>application/zip</mime_type><hash>ff27ce0115797479d4a21e28885fcde5</hash><hash_type>MD5</hash_type><filesize>77092</filesize><mtime>2025-12-17 14:05:24</mtime><url>https://researchdata.bath.ac.uk/1625/4/Impedance%20data.zip</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>4</pos><placement>5</placement><mime_type>application/zip</mime_type><format>other</format><formatdesc>Impedance results of dense and porous PZT NCE51 fabricated at various freeze-cast cooling rates.</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>Impedance data.zip</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19709"><docid>19709</docid><rev_number>10</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/80548"><fileid>80548</fileid><datasetid>document</datasetid><objectid>19709</objectid><filename>PE loops.zip</filename><mime_type>application/zip</mime_type><hash>8a07137f3f686bc7a1653c80b4a2e361</hash><hash_type>MD5</hash_type><filesize>661460</filesize><mtime>2025-12-17 14:06:19</mtime><url>https://researchdata.bath.ac.uk/1625/5/PE%20loops.zip</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>5</pos><placement>6</placement><mime_type>application/zip</mime_type><format>other</format><formatdesc>Hysteresis polarization-field (P-E) data of freeze-cast and dense PZT NCE51 evaluated at a field of 12 kV/cm</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>PE loops.zip</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19710"><docid>19710</docid><rev_number>8</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/80550"><fileid>80550</fileid><datasetid>document</datasetid><objectid>19710</objectid><filename>SEM images.zip</filename><mime_type>application/zip</mime_type><hash>18a8ade875675b5700f6d5532d8dad86</hash><hash_type>MD5</hash_type><filesize>18383313</filesize><mtime>2025-12-17 14:06:59</mtime><url>https://researchdata.bath.ac.uk/1625/6/SEM%20images.zip</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>6</pos><placement>4</placement><mime_type>application/zip</mime_type><format>other</format><formatdesc>Scanning electron micrographs illustrating the microstructure of freeze-cast PZT NCE51 fabricated at various cooling rates.</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>SEM images.zip</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19711"><docid>19711</docid><rev_number>8</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/80552"><fileid>80552</fileid><datasetid>document</datasetid><objectid>19711</objectid><filename>Depolarization.zip</filename><mime_type>application/zip</mime_type><hash>cfbf297fe31f574844cb08dd48481c02</hash><hash_type>MD5</hash_type><filesize>751993</filesize><mtime>2025-12-17 14:08:35</mtime><url>https://researchdata.bath.ac.uk/1625/7/Depolarization.zip</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>7</pos><placement>7</placement><mime_type>application/zip</mime_type><format>other</format><formatdesc>These files outline the temperature dependent piezoelectric charge coefficient (d₃₃), and relative permittivity at constant stress εᵣ of freeze-cast PZT NCE51 fabricated at cooling rates ranging from 1 to 4 °C/min.</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>Depolarization.zip</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19712"><docid>19712</docid><rev_number>8</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/80554"><fileid>80554</fileid><datasetid>document</datasetid><objectid>19712</objectid><filename>FE model - poling.zip</filename><mime_type>application/zip</mime_type><hash>a72fc160a196bd6176a2f56da8584dd7</hash><hash_type>MD5</hash_type><filesize>123730619</filesize><mtime>2025-12-17 14:11:03</mtime><url>https://researchdata.bath.ac.uk/1625/8/FE%20model%20-%20poling.zip</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>8</pos><placement>10</placement><mime_type>application/zip</mime_type><format>other</format><formatdesc>Finite element ANSYS APDL code to demonstrate the effects of 1) wall thickness (i.e., mechanical clamping), 2) pore channel effects (i.e., ceramic grains within pore channels) and 3) wall defects (i.e., pores within ceramic walls) on the bulk electromechanical and functional properties of 2-2 connectivity type freeze-cast ceramics</formatdesc><language>en</language><security>public</security><license>cc_mit</license><main>FE model - poling.zip</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>code</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19935"><docid>19935</docid><rev_number>3</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/81954"><fileid>81954</fileid><datasetid>document</datasetid><objectid>19935</objectid><filename>Freeze-cast_PZT_NCE51_electromechanical_properties.xlsx</filename><mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type><hash>db151afe71ed91baa3d95fac17afe314</hash><hash_type>MD5</hash_type><filesize>20643</filesize><mtime>2026-02-20 11:37:18</mtime><url>https://researchdata.bath.ac.uk/1625/10/Freeze-cast_PZT_NCE51_electromechanical_properties.xlsx</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>10</pos><placement>1</placement><mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type><format>other</format><formatdesc>Datasheet summarizing the geometry, piezoelectric charge coefficient (d₃₃), and relative permittivity at constant stress εᵣ of freeze-cast PZT NCE51 fabricated at cooling rates ranging from 1 to 4 °C/min.</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>Freeze-cast_PZT_NCE51_electromechanical_properties.xlsx</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19936"><docid>19936</docid><rev_number>3</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/81967"><fileid>81967</fileid><datasetid>document</datasetid><objectid>19936</objectid><filename>Freeze-cast_PZT_NCE51_mechanical_properties.xlsx</filename><mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type><hash>5294ca637dfd89eb4085a4379520c7e6</hash><hash_type>MD5</hash_type><filesize>18025</filesize><mtime>2026-02-20 11:38:05</mtime><url>https://researchdata.bath.ac.uk/1625/11/Freeze-cast_PZT_NCE51_mechanical_properties.xlsx</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>11</pos><placement>2</placement><mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type><format>other</format><formatdesc>Datasheet summarizing the geometry and the compressive strength of freeze-cast PZT NCE51 fabricated at cooling rates ranging from 1 to 4 °C/min.</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>Freeze-cast_PZT_NCE51_mechanical_properties.xlsx</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19937"><docid>19937</docid><rev_number>3</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/81996"><fileid>81996</fileid><datasetid>document</datasetid><objectid>19937</objectid><filename>Instron_strain_calibration.zip</filename><mime_type>application/zip</mime_type><hash>a476511207a387a5202ca53be5254e43</hash><hash_type>MD5</hash_type><filesize>74122</filesize><mtime>2026-02-20 11:40:37</mtime><url>https://researchdata.bath.ac.uk/1625/12/Instron_strain_calibration.zip</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>12</pos><placement>9</placement><mime_type>application/zip</mime_type><format>other</format><formatdesc>This folder outlines the compression testing data of aluminium 6063-T3, brass CZ121 and PZT NCE51 in pellet forms, used to calibrate the strain calculated from the Instron testing machine.</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>Instron_strain_calibration.zip</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19938"><docid>19938</docid><rev_number>3</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/82009"><fileid>82009</fileid><datasetid>document</datasetid><objectid>19938</objectid><filename>FE_simulation_PZT_NCE51_2-2_microstructures.xlsx</filename><mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type><hash>0ce436c257f66643a8f3d3bc49631eae</hash><hash_type>MD5</hash_type><filesize>30869</filesize><mtime>2026-02-20 12:00:23</mtime><url>https://researchdata.bath.ac.uk/1625/13/FE_simulation_PZT_NCE51_2-2_microstructures.xlsx</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>13</pos><placement>8</placement><mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type><format>other</format><formatdesc>Finite element results demonstrating the effects of 1) wall thickness (i.e., mechanical clamping), 2) pore channel effects (i.e., ceramic grains within pore channels) and 3) wall defects (i.e., pores within ceramic walls) on the bulk electromechanical and functional properties of 2-2 connectivity type freeze-cast ceramics</formatdesc><language>en</language><security>public</security><license>cc_by</license><main>FE_simulation_PZT_NCE51_2-2_microstructures.xlsx</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>data</content><relation></relation><media></media></document><document id="https://researchdata.bath.ac.uk/id/document/19944"><docid>19944</docid><rev_number>4</rev_number><files><file id="https://researchdata.bath.ac.uk/id/file/82213"><fileid>82213</fileid><datasetid>document</datasetid><objectid>19944</objectid><filename>FE model - residual stress.zip</filename><mime_type>application/zip</mime_type><hash>4a413b021e8fa2768fbed6b8e14abd7b</hash><hash_type>MD5</hash_type><filesize>94445747</filesize><mtime>2026-03-04 11:56:19</mtime><url>https://researchdata.bath.ac.uk/1625/14/FE%20model%20-%20residual%20stress.zip</url><data encoding="base64"></data></file></files><eprintid>1625</eprintid><pos>14</pos><placement>14</placement><mime_type>application/zip</mime_type><format>other</format><formatdesc>Finite element ANSYS APDL code to demonstrate the effects of wall thickness (i.e., mechanical clamping) on the residual stress upon the release of the applied field.</formatdesc><language>en</language><security>public</security><license>cc_mit</license><main>FE model - residual stress.zip</main><date_embargo></date_embargo><date_embargo_retained></date_embargo_retained><embargo_reason></embargo_reason><content>code</content><relation></relation><media></media></document></documents>
