<?xml version='1.0' encoding='utf-8'?>
<eprints xmlns='http://eprints.org/ep2/data/2.0'>
  <eprint id='https://researchdata.bath.ac.uk/id/eprint/660'>
    <eprintid>660</eprintid>
    <rev_number>37</rev_number>
    <documents>
      <document id='https://researchdata.bath.ac.uk/id/document/11464'>
        <docid>11464</docid>
        <rev_number>5</rev_number>
        <files>
          <file id='https://researchdata.bath.ac.uk/id/file/33512'>
            <fileid>33512</fileid>
            <datasetid>document</datasetid>
            <objectid>11464</objectid>
            <filename>Non-locking screw insertion data.xlsx</filename>
            <mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type>
            <hash>312ca4a605ea23ab483469542db3ea0b</hash>
            <hash_type>MD5</hash_type>
            <filesize>65583</filesize>
            <mtime>2019-07-13 17:11:44</mtime>
            <url>https://researchdata.bath.ac.uk/660/1/Non-locking%20screw%20insertion%20data.xlsx</url>
          </file>
        </files>
        <eprintid>660</eprintid>
        <pos>1</pos>
        <placement>1</placement>
        <mime_type>application/vnd.openxmlformats-officedocument.spreadsheetml.sheet</mime_type>
        <format>other</format>
        <formatdesc>Raw data for: Fletcher, J., Ehrhardt, B., MacLeod, A., Whitehouse, M., Gill, H. &amp; Preatoni, E. 2019. Non-locking screw insertion: No benefit seen if tightness exceeds 80% of the maximum torque. Clinical Biomechanics https://doi.org/10.1016/j.clinbiomech.2019.07.009</formatdesc>
        <language>en</language>
        <security>public</security>
        <license>cc_by</license>
        <main>Non-locking screw insertion data.xlsx</main>
        <content>data</content>
      </document>
      <document id='https://researchdata.bath.ac.uk/id/document/11467'>
        <docid>11467</docid>
        <rev_number>3</rev_number>
        <files>
          <file id='https://researchdata.bath.ac.uk/id/file/33531'>
            <fileid>33531</fileid>
            <datasetid>document</datasetid>
            <objectid>11467</objectid>
            <filename>Explanation of data for non-locking screw insertion.docx</filename>
            <mime_type>application/vnd.openxmlformats-officedocument.wordprocessingml.document</mime_type>
            <hash>097b2ad85a9e941df26db91b9309e9e5</hash>
            <hash_type>MD5</hash_type>
            <filesize>15474</filesize>
            <mtime>2019-07-17 11:07:56</mtime>
            <url>https://researchdata.bath.ac.uk/660/4/Explanation%20of%20data%20for%20non-locking%20screw%20insertion.docx</url>
          </file>
        </files>
        <eprintid>660</eprintid>
        <pos>4</pos>
        <placement>4</placement>
        <mime_type>application/vnd.openxmlformats-officedocument.wordprocessingml.document</mime_type>
        <format>other</format>
        <formatdesc>Raw data description</formatdesc>
        <language>en</language>
        <security>public</security>
        <license>cc_by</license>
        <main>Explanation of data for non-locking screw insertion.docx</main>
        <content>documentation</content>
      </document>
      <document id='https://researchdata.bath.ac.uk/id/document/11468'>
        <docid>11468</docid>
        <rev_number>1</rev_number>
        <files>
          <file id='https://researchdata.bath.ac.uk/id/file/33535'>
            <fileid>33535</fileid>
            <datasetid>document</datasetid>
            <objectid>11468</objectid>
            <filename>indexcodes.txt</filename>
            <mime_type>text/plain</mime_type>
            <hash>b095ed627f7fe8f88c2a33380fe3fcb0</hash>
            <hash_type>MD5</hash_type>
            <filesize>751</filesize>
            <mtime>2019-07-17 11:18:24</mtime>
            <url>https://researchdata.bath.ac.uk/660/5/indexcodes.txt</url>
          </file>
        </files>
        <eprintid>660</eprintid>
        <pos>5</pos>
        <placement>5</placement>
        <mime_type>text/plain</mime_type>
        <format>other</format>
        <formatdesc>Generate index codes conversion from other to indexcodes</formatdesc>
        <language>en</language>
        <security>validuser</security>
        <main>indexcodes.txt</main>
        <relation>
          <item>
            <type>http://eprints.org/relation/isVersionOf</type>
            <uri>https://researchdata.bath.ac.uk/id/document/11467</uri>
          </item>
          <item>
            <type>http://eprints.org/relation/isVolatileVersionOf</type>
            <uri>https://researchdata.bath.ac.uk/id/document/11467</uri>
          </item>
          <item>
            <type>http://eprints.org/relation/isIndexCodesVersionOf</type>
            <uri>https://researchdata.bath.ac.uk/id/document/11467</uri>
          </item>
        </relation>
      </document>
    </documents>
    <eprint_status>archive</eprint_status>
    <userid>7550</userid>
    <dir>disk0/00/00/06/60</dir>
    <datestamp>2019-08-07 08:22:36</datestamp>
    <lastmod>2024-07-01 15:09:30</lastmod>
    <status_changed>2019-08-07 08:22:36</status_changed>
    <type>data_collection</type>
    <metadata_visibility>show</metadata_visibility>
    <creators>
      <item>
        <name>
          <family>Fletcher</family>
          <given>James</given>
        </name>
        <id>J.W.A.Fletcher@bath.ac.uk</id>
        <orcid>0000-0003-4147-5013</orcid>
        <affiliation>University of Bath</affiliation>
        <contact>TRUE</contact>
      </item>
      <item>
        <name>
          <family>Ehrhardt</family>
          <given>Beate</given>
        </name>
        <id>B.Ehrhardt@bath.ac.uk</id>
        <orcid>0000-0002-4476-3611</orcid>
        <affiliation>University of Bath</affiliation>
        <contact>FALSE</contact>
      </item>
      <item>
        <name>
          <family>MacLeod</family>
          <given>Alisdair</given>
        </name>
        <id>A.Macleod@bath.ac.uk</id>
        <orcid>0000-0001-6981-8087</orcid>
        <affiliation>University of Bath</affiliation>
        <contact>FALSE</contact>
      </item>
      <item>
        <name>
          <family>Whitehouse</family>
          <given>Michael R.</given>
        </name>
        <id>Michael.whitehouse@bristol.ac.uk</id>
        <orcid>0000-0003-2436-9024</orcid>
        <affiliation>University of Bristol</affiliation>
        <contact>FALSE</contact>
      </item>
      <item>
        <name>
          <family>Gill</family>
          <given>Harinderjit</given>
        </name>
        <id>R.Gill@bath.ac.uk</id>
        <orcid>0000-0002-7740-2062</orcid>
        <affiliation>University of Bath</affiliation>
        <contact>FALSE</contact>
      </item>
      <item>
        <name>
          <family>Preatoni</family>
          <given>Ezio</given>
        </name>
        <id>E.Preatoni@bath.ac.uk</id>
        <orcid>0000-0001-5383-7072</orcid>
        <affiliation>University of Bath</affiliation>
        <contact>FALSE</contact>
      </item>
    </creators>
    <title>Dataset for &quot;Non-locking screw insertion: no benefit seen if tightness exceeds 80% of the maximum torque&quot;</title>
    <subjects>
      <item>GS0020</item>
      <item>GS0070</item>
    </subjects>
    <divisions>
      <item>dept_mech_eng</item>
      <item>dept_health</item>
    </divisions>
    <abstract>Screws are the most commonly used orthopaedic implant, however they are frequently overtightened when inserted. Using screw, bone and screw hole characteristics, maximum torque for a screw hole is predicted prior to insertion. Using this, optimum tightness as a percentage of the maximum torque is investigated as functions of compression and pullout forces. This data set provides the raw data for these investigations. The methodology is described in detail in the related manuscript: Fletcher, J., Ehrhardt, B., MacLeod, A., Whitehouse, M., Gill, H. &amp; Preatoni, E. 2019. Non-locking screw insertion: No benefit seen if tightness exceeds 80% of the maximum torque. Clinical Biomechanics. https://doi.org/10.1016/j.clinbiomech.2019.07.009</abstract>
    <date>2019-07-09</date>
    <publisher>University of Bath</publisher>
    <full_text_status>public</full_text_status>
    <corp_contributors>
      <item>
        <type>RightsHolder</type>
        <corpname>University of Bath</corpname>
      </item>
    </corp_contributors>
    <funding>
      <item>
        <funder_name>Royal College of Surgeons of England</funder_name>
        <funder_id>https://doi.org/10.13039/501100000297</funder_id>
        <project_name>Fellowship for James Fletcher - Optimal surgical techniques to reduce screw failure in fragility fractures</project_name>
      </item>
      <item>
        <funder_name>David Telling Charitable Trust</funder_name>
        <funder_id>https://doi.org/10.13039/501100020276</funder_id>
        <project_name>Improving Fracture Fixation - The Role of Insertion Forces on Construct Stability</project_name>
      </item>
    </funding>
    <research_centres>
      <item>cent_ortho_bio</item>
      <item>bimi</item>
    </research_centres>
    <collection_method>Biomechanical testing using juvenile bovine bone</collection_method>
    <techinfo>&apos;R&apos; software, v3.3.3 (R: A language and environment for statistical computing. R Foundation for Statistical Computing).</techinfo>
    <language>en</language>
    <version>1</version>
    <doi>10.15125/BATH-00660</doi>
    <related_resources>
      <item>
        <link>https://doi.org/10.1016/j.clinbiomech.2019.07.009</link>
        <type>pub</type>
      </item>
    </related_resources>
    <access_types>
      <item>open</item>
    </access_types>
  </eprint>
</eprints>
