Dataset for mid IR gas laser
The data to generate figures 3 – 8:
1. Csv file (Figure 3(a)): contains the attenuations of the feedback fiber for figure 3(a) ;
2. Csv file (Figure 3(b)): contains the P(9) absorption line for figure 3 (b);
3. Csv file (Figure 4(a)): contains optical spectra for different pump transitions in figure 4(a);
4. Csv file (Figure 5(a)): contains the CW pump power/output power and stability of laser output as a function of time for figure 5(a);
5. Csv file (Figure 5(b)): contains the stability of laser output as a function of time for figure 5(b);
6. Csv file (Figure 5(b) inset): contains the mode profile of 3um laser for figure 5(b) inset;
7. Csv file (Figure 6): contains the Measured output power as a function of pump repetition rate for figure 6;
8. Csv file (Figure 7): contains pump power/output power at selected repetition rates shown in figure 7.
9. Zip file (Figure 8): contains csv file of radio frequency spectra (a), optical spectra (b) and time dependence (c) for the pump (blue) and the laser (red) at selected repetition rates shown in figure 8.
Cite this dataset as:
Knight, J.,
Wadsworth, W.,
Yu, F.,
Abu Hassan, M.,
2016.
Dataset for mid IR gas laser.
Bath: University of Bath Research Data Archive.
Available from: https://doi.org/10.15125/BATH-00101.
Export
Data
Figure_3(a) … feedback_fiber.csv
text/plain (16kB)
The fiber attenuation was measured by using the cut-back method. The Tungsten lamp was used as the whitelight source. A 300 mm focal length scanning spectrometer (Bentham Instruments TMc300) was used for all spectral measurements at mid-infrared wavelengths, which has a 300 lines/mm grating and a liquid-nitrogen-cooled InAs detector (Electro-Optical Systems S-010-LN4).
Figure_3(b)-P(9)_absorption_line.csv
text/plain (496B)
The acetylene (12C2H2) P(9) absorption near 1530 nm was measured by recording the transmission of CW laser after 10 m gain fiber filled with 0.3 mbar acetylene gas. A thermal power meter (Ophir 3A-SH) was used to measure the laser power. The tunable laser diode (ID Photonics GMBH, CoBrite DX1, linewidth <100 kHz, maximum output power ~40 mW) was used as a source after amplification.
Figure_4(a)-Measured … lines.csv
text/plain (177kB)
The spectral measurements were performed using a 300 mm focal length scanning spectrometer (Bentham Instruments TMc300) fitted with a 300 lines/mm grating and a liquid-nitrogen-cooled InAs detector (Electro-Optical Systems S-010-LN4).
Figure_5(a) … CW_pumping.csv
text/plain (174B)
The pump powers referred to in Figs 5 (a) were measured after the dichroic mirror and before the input lens and window.Measurements of optical powers were performed using a thermal power meter (Ophir 3A-SH).
Figure_5(b) … laser_output.csv
text/plain (1MB)
Stability of laser output as a function of time in the fig 5 (b), was measured at 10 Hz sampling rate over more than one hour. A high gain detector (Thorlab PDA20H-EC) was used to directly measure the lasing power.
Figure_5_(b)_-_Inset.csv
text/plain (17kB)
The mode profile (inset Fig 5 (b)), was measured by using a two-dimensional scan with a short piece of feedback fiber (less than 3 m) across the output beam. The fiber was mounted on a 2D scanning translation device and connected with a high gain detector (Thorlab PDA20H-EC). The whole scan was controlled by LABView software.
Figure_6_Measured … rate.csv
text/plain (5kB)
All the pump powers shown in Figure 6 were measured after the dichroic mirror with a thermal power meter (Ophir 3A-SH).
Figure_7_Pump … repetition_rates.csv
text/plain (605B)
All the pump powers shown in Figure 7 were measured after the dichroic mirror with a thermal power meter (Ophir 3A-SH).
Figure_8.zip
application/zip (55kB)
Time-dependent (Figs 8 (a & c)) measurements used a high speed HgCdTe detector (Vigo PVI-3.4-1×1- TO39-NO WINDOW-35, 1ns rise time) for 3.1 µm and a high speed InGaAs detector (Thorlabs DET01CFC) for 1.5 µm.A 350 MHz digital oscilloscope (Agilent InfiniiVision DSO-X-3032A) and 6 GHz spectrum analyzer (Agilent CSA Spectrum Analyzer) were used for measurements.The spectral measurements in Fig. 8b, was used a liquid-nitrogen-cooled InAs detector (Electro-Optical Systems S-010-LN4).
Creators
Jonathan Knight
University of Bath
William Wadsworth
University of Bath
Fei Yu
University of Bath
Muhammad Rosdi Abu Hassan
University of Bath
Contributors
University of Bath
Rights Holder
Coverage
Temporal coverage:
From 1 November 2014 to 10 June 2015
Documentation
Data collection method:
The fiber attenuation was measured by using the cut-back method. The Tungsten lamp was used as the whitelight source. A 300 mm focal length scanning spectrometer (Bentham Instruments TMc300) was used for all spectral measurements at mid-infrared wavelengths, which has a 300 lines/mm grating and a liquid-nitrogen-cooled InAs detector (Electro-Optical Systems S-010-LN4). . The acetylene (12C2H2) P(9) absorption near 1530 nm was measured by recording the transmission of CW laser after 10 m gain fiber filled with 0.3 mbar acetylene gas. A thermal power meter (Ophir 3A-SH) was used to measure the laser power. The tunable laser diode (ID Photonics GMBH, CoBrite DX1, linewidth <100 kHz, maximum output power ~40 mW) was used as a source after amplification. All the pump powers shown in Figs 4 (a) and 6 were measured after the dichroic mirror with a thermal power meter (Ophir 3A-SH). Stability of laser output as a function of time in the fig 5 (b), was measured at 10 Hz sampling rate over more than one hour. A high gain detector (Thorlab PDA20H-EC) was used to directly measure the lasing power. The mode profile (inset Fig 5 (b)), was measured by using a two-dimensional scan with a short piece of feedback fiber (less than 3 m) across the output beam. The fiber was mounted on a 2D scanning translation device and connected with a high gain detector (Thorlab PDA20H-EC). The whole scan was controlled by LABView software. Time-dependent (Figs 8 (a & c)) measurements used a high speed HgCdTe detector (Vigo PVI-3.4-1×1- TO39-NO WINDOW-35, 1ns rise time) for 3.1 µm and a high speed InGaAs detector (Thorlabs DET01CFC) for 1.5 µm.A 350 MHz digital oscilloscope (Agilent InfiniiVision DSO-X-3032A) and 6 GHz spectrum analyzer (Agilent CSA Spectrum Analyzer) were used for measurements
Documentation Files
ReadMe.txt
text/plain (2kB)
Funders
Engineering and Physical Sciences Research Council
https://doi.org/10.13039/501100000266
New Fibres for New Lasers - Photonic Crystal Fibre Optics for the Delivery of High-Power Light
EP/I011315/1
Publication details
Publication date: 2016
by: University of Bath
Version: 1
DOI: https://doi.org/10.15125/BATH-00101
URL for this record: https://researchdata.bath.ac.uk/id/eprint/101
Related papers and books
Abu Hassan, M. R., Yu, F., Wadsworth, W. J., and Knight, J. C., 2016. Cavity-based mid-IR fiber gas laser pumped by a diode laser. Optica, 3(3), 218. Available from: https://doi.org/10.1364/optica.3.000218.
Contact information
Please contact the Research Data Service in the first instance for all matters concerning this item.
Contact person: Jonathan Knight
Faculty of Science
Physics